top of page
Hanna Marine Master HI97105

Pre-Orders with an Expected time of Delivery in 2 - 4 Weeks

  • Alkalinity
  • Calcium
  • Low Range and High Range Nitrate
  • Ultra Low Range Nitrite
  • Ultra Low Range Phosphate
  • pH

All-In-One Testing with Precise Results for Reef Tanks
The HI97105 Marine Master Photometer is a waterproof tester that combines accuracy and ease of use into one simple, portable design. Its advanced, lab-quality optical system ensures accurate readings while its user-friendly design and built-in tutorials make it perfect for marine scientists and aquarium hobbyists alike.

  • Precise and advanced LED optical system
  • No warm up time needed before taking a measurement
  • Waterproof and floating IP67 meter design
  • CAL Check validation and calibration
  • Consolidates testing needs into one unit
  • Includes auto-data logging features to easily record water testing results
  • On-screen tutorial mode guides users step-by-step through the measurement process
  • Option to select measurement location for better tracking consistency
  • Auto shut-off
  • Rugged carrying case included

 

Testing Parameter

Specifications

Marine
Alkalinity

Range0.0 to 20.0 dkH
0 to 357 ppm (as CaCO3)
Resolution0.1 dkH
Accuracy±0.3 dKH ±5 % of reading at 25 °C
±5 ppm ±5 % of reading at 25 °C
MethodColorimetric Method - The reaction causes a distinctive range of colors from yellow to greenish blue to develop

Marine
Calcium

Range200 to 600 ppm
Resolution1 ppm
Accuracy±6 % of reading at 25 °C
MethodAdaptation of the Zincon Method

Marine
Nitrate

Range0.00 to 5.00 ppm (as NO3¯)
0.0 to 75.0 ppm (as NO3¯)
Resolution0.01 ppm
0.1 ppm
Accuracy0 to 200 ppb (as NO2¯-N)
MethodAdaptation of the Zincon Method
Colorimetric Method The reaction between nitrate and the reagent causes a pink/violet tint in the sample.

Marine
Nitrite ULR

Range0 to 200 ppb (as NO2¯-N)
Resolution1 ppb
Accuracy±10 ppb ±4 % of reading at 25 °C
MethodAdaptation of the EPA Diazotization Method 354.1 - The reaction between nitrite and the reagent causes a pink tint in the sample.

Marine
pH

Range6.3 to 8.6 pH
Resolution0.1 pH
Accuracy±0.2 pH of reading at 25 °C
MethodColorimetric Adaptation of the Phenol Red Method

Marine
Phosphate LR

Range0.00 to 0.90 ppm
Resolution0.01 ppm
Accuracy±0.02 ppm ±5 % of reading at 25 °C
MethodAdaptation of Standard Methods for the Examination of Water and Wastewater, 20th Edition, Ascorbic Acid Method - The reaction between phosphate and the reagent causes a blue tint in the sample.

General

Light SourceLight emitting diode
Light DetectorSilicon photocell
Bandpass Filter Bandwidth8 nm
Bandpass Filter Wavelength Accuracy±1.0 nm
Logging200 readings
Power Supply1.5 V AA Alkaline (3 pcs.)
Battery Life> 800 measurements (without backlight)
Auto-offAfter 15 minutes of inactivity (30 minutes before a READ measurement)
Environment0 to 50 °C (32 to 122 °F); 0 to 100% RH, non-serviceable
Dimensions142.5 x 102.5 x 50.5 mm (5.6" x 4.0" x 2.0")
Weight380 g (13.4 oz.); with batteries

Hanna Marine Master HI97105